Ieee std 80 2000 revision of ieee std 80 1986 ieee guide for safety in ac substation grounding sponsor substations committee of the ieee power engineering society approved 30 january 2000 ieee sa standards board abstract. Ieee recommended practice for testing insulation resistance. The newly revised ieee standard 80 2000 1 has been approved for some time and has been used by engineers and professionals in grounding design and analysis. Apr 12, 2020 falls under the category of distribution substation with relevant ieee code of standard and with clause number. Dec 12, 2018 ieee std 802000 pdf 15 may ieee std 80 revision of. It must not be used or referred to as a zambian standard.
Ieee std 4872007, recommended practice for the protection of wireline communication facilities serving electric supply locations. Download ieee std 80 2000 pdf from 16 mb, ieee std 80 2000 2 pdf from 16 mb free from tradownload. The design of the substation grounding grid is often carried out to meet the ieee. Teee q0engl 2000 mm 4805702 580480 432 mm ieee std 802000 reusion of ieee st 601086 ieee guide for safety in ac substation grounding sponsor substations committee of the ieee power engineering society approved 30 january 2000 ieeesa standards board abstract. Grounding grid design in electrical power substation using. Ieee websites place cookies on your device to give you the best user experience. There are changes in standard 80 2000 with respect to standard 80 1986 2, which affect. Design and analysis of substation grounding grid with and. Ieee std 80 2000 ieee guide for safety in ac substation grounding sponsor substations committee of the ieee power engineering society. Ieee p80d6 draft guide for safety in ac substation grounding.
Delivering full text access to the worlds highest quality technical literature in engineering and technology. Sep 19, 2018 in electrical substations, ground grid ieee 80 2000 significant importance for the safety of personnel and delicate equipment ieee std analysis of ground potential rise of substation ground grid isee in twolayer earth using ieee 80 2000 earth parameters of case click here to join engtips and talk with other members. Design a substation grounding system based on ieee std 80 2000 1, ieee std 811983 2, ieee std 8372002 3, standards in general, assure that a person in the vicinity of grounded facilities is not exposed to the danger of critical electric shock. Ieee std 9981996, ieee guide for direct lightning stroke shielding of substations. Ansiieee std 802000, ieee guide for safety in ac substation grounding. Teee q0engl 2000 mm 4805702 580480 432 mm ieee std 802000 reusion of ieee st 601086 ieee guide for safety in ac. Ieee 94a, was released in 2000, request pdf on researchgate comparison of iec 4791 and ieee std 80 on grounding safety criteria this paper provides a comparison of the safety criteria of two widely accepted standards. Grounding standard 802000 with respect to the 1986 version standard 801986, which affect the.
Three editions of ieee standard 80 1961, 1976, and 1986 had been published before the 2000 edition. The intent of this guide is to provide guidance and information pertinent to safe grounding practices in ac substation design. Please choose whether or not you want other users to be able to see on your 802000 that this library is a favorite of yours. Ieee std 80 2000 pdf 15 may ieee std 80 revision of. They considered the effects of uniform and layered soil in earthing. Ieee std 80 is quite descriptive, detailed and easy to follow, so only an overview will be presented here and ieee std 80 should be consulted for further details although references will be given herein. Ieee std 80 1986 has been revised as ieee std 80 2000. Outdoor ac substations, either conventional or gasinsulated, are covered in this guide. This introduction is not part of ieee std 802000, ieee guide for safety.
Insulation resistance measurement has been recommended and used for more than half a century to evaluate the condition of electrical insulation. This introduction is not part of ieee std 43 2000, ieee recommended practice for testing insulation resistance of rotating machinery. Whereas individual insulation resistance measurements may. Ieee guide for safety in ac substation grounding ieee std 802000. Oct 18, 2018 the ieee std 80 2000 program ieee std 80 2000 used in the mathematical modeling is based on the method proposed by heppe, which allows obtaining the grounding parameters for homogeneous soil and soil stratified sfd two layers. Tolerable potential across 50 kg body, step voltage, 4 of 2000. A comparison of iec 4791 and ieee std 80 on grounding safety. Correction sheet to ieee std 802000 sh94807 21 february 2007 page 24, figure 12basic shock situations, should be replaced with the following figure. Disenado con ieee80 y evaluado con mef find, read and cite all the research you need on.
Standard 80 2000 revision of ieee standard 80 1986. The two standards differ in their definition of the permissible body current and their definition of body resistance. The content of this correction sheet may not be modified. Ieee 80 2000 guide for safety in substation grounding. Ieee std 80 20 revision of ieee std 80 2000 incoporates ieee std 80 20cor 12015 ieee guide for safety in ac substation. This information has been incorporated into the second printing of ieee std 80 2000. Determine the required grid conductor specifications. Ieee standards interpretation for ieee std 801986 ieee. Ieee std 2001975 2 a group of parts shall not be treated as a subassembly unless it is one or more of the following. Introduction the design consideration of substation grounding is important for providing low resistance path to ground, to allow.
Pdf ieee std 802000 ieee guide for safety in ac substation. Std 802000 requirements of grounding resistance, touch voltage and step. Pdf this paper discusses the major changes in the 2000 version of ieee guide for safety in ac substation grounding standard 802000 with respect to. This correction sheet may not be sold, licensed or otherwise distributed for any commercial purposes whatsoever. Step and touch potentials, ground potential rise, absolute potential, ieee std. The specific purposes of this guide are to a establish, as a basis for design, the safe limits of potential differences that can exist in a substation under fault conditions between points that can be contacted by the human body. This occurs because the terms in ieee std 100 represent only those defined in the existing or past body of ieee standards. This study presents an advanced methodology and a computer model for analysis of grounding systems conforming to standards ieee std 802000, ieee std 81.